GAM900 - Acceleration sensors
Technical data - electrical ratings
Voltage supply
10...30 VDC
Reverse polarity protection
Yes
Consumption w/o load
?200 mA (24 VDC)
Initializing time
?2000 ms after power on
Interface
CANopen®
Analog (4...20 mA or 0...10 V)
Frequency bands
6 (configurable)
Measuring range
�2 g
Resolution
<4 mg
Accuracy 3? (with band pass filtering)
=35 mg (in the range of �1000 mg)
=10 mg (in the range of �250 mg)
Interference immunity
DIN EN 61000-6-2
EN 61326-3-1
Emitted interference
DIN EN 61000-6-4
Status indicator
DUO-LED integrated in housing
Approval
UL approval / E63076
Option: PLd according to
EN ISO 13849-1:2008 +AC:2009
SIL CL2 according to
EN 62061:2005
+AC:2010 +A1:2013
SIL2 according to
IEC 61508-1..7:2010
Technical data - mechanical design
Dimensions W x H x L
55 x 30 x 90 mm
Protection DIN EN 60529
IP 67
Material
GAM900-M: Aluminium
GAM900-P: glass-fiber reinforced plastic
Operating temperature
-40...+85 °C
Resistance
DIN EN 60068-2-6
Vibration 20 g, 60-2000 Hz
DIN EN 60068-2-27
Shock 100 g, 6 ms
Weight approx.
200 g (plastic)
250 g (Aluminium)
Connection
Connector M12, 12-pin
Visit the Greenbank Machinery and Plant Ltd website for more information on GAM900 - Acceleration sensors