Process Details:
Large cryogenic mill designed for cryogenic grinding and pulverising tough and temperature sensitive samples immersed in liquid nitrogen.
Supply:
Stainless steel desktop acoustic enclosure 760mm wide x 720mm deep x 710mm high
Product selection:
Enclosure needed to be lockable and able to collect displaced nitrogen also allow full access and be suitable for a clean room laboratory environment.
Performance:
Enclosure performance was selected to reduce noise by approx. 15dBA to achieve NR30 in the laboratory environment.